{"id":16890,"date":"2026-08-19T09:59:18","date_gmt":"2026-08-19T07:59:18","guid":{"rendered":"https:\/\/www.trianon-echangeur.com\/how-do-you-size-a-heat-exchanger\/"},"modified":"2026-08-20T10:08:46","modified_gmt":"2026-08-20T08:08:46","slug":"how-do-you-size-a-heat-exchanger","status":"publish","type":"page","link":"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/","title":{"rendered":"How do you size a heat exchanger?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"16890\" class=\"elementor elementor-16890 elementor-16829\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ab259f6 elementor-section-height-min-height elementor-section-boxed elementor-section-height-default elementor-section-items-middle\" data-id=\"ab259f6\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ae71777\" data-id=\"ae71777\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-499cf57 elementor-widget elementor-widget-text-editor\" data-id=\"499cf57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>FAQ &#8211; Heat exchangers<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd2da20 elementor-widget elementor-widget-heading\" data-id=\"fd2da20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">How do you size a heat exchanger?<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1038d40 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1038d40\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-b7aa209\" data-id=\"b7aa209\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c47662c elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"c47662c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">How do you size a heat exchanger?<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b4ccbe elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"7b4ccbe\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:150}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f668cb7 elementor-widget elementor-widget-text-editor\" data-id=\"f668cb7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The design of a heat exchanger involves defining a solution capable of transferring thermal power between two fluids under specific operating conditions. It is not simply a matter of selecting equipment based on its dimensions: it is necessary to analyse the fluids, temperatures, flow rates, pressure, pressure drops, space requirements, materials, the environment and maintenance requirements. <\/p><p>In industry, an air-to-water, air-to-steam, air-to-flue gas or air-to-air heat exchanger, a finned coil or a heat recovery unit are not subject to the same constraints. Each application has its own specific parameters: inlet temperature, outlet temperature, nature of the fluids, operating pressure, risk of fouling, corrosion, integration into an existing system or replacement with an identical unit. <\/p><p>Trianon \u00c9changeur designs bespoke heat exchangers based on the project\u2019s technical specifications. The aim is to provide a solution that is consistent with the expected performance, installation constraints and actual operating conditions. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-16a3281\" data-id=\"16a3281\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a3117cb elementor-widget elementor-widget-image\" data-id=\"a3117cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"550\" height=\"402\" src=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/dimmensionner-un-echangeur-thermique.png\" class=\"attachment-large size-large wp-image-16885\" alt=\"\" srcset=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/dimmensionner-un-echangeur-thermique.png 550w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/dimmensionner-un-echangeur-thermique-300x219.png 300w\" sizes=\"(max-width: 550px) 100vw, 550px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7dafe4c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7dafe4c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-d38c759\" data-id=\"d38c759\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-31bab8d elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"31bab8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why is the sizing of a heat exchanger important?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33b20e2 elementor-widget elementor-widget-text-editor\" data-id=\"33b20e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>An incorrectly sized heat exchanger can lead to a loss of performance, higher energy consumption, excessive pressure drops or premature wear and tear on the system.<\/p><p>An undersized heat exchanger may not achieve the required thermal output. An oversized heat exchanger may be more expensive, take up more space and, in some cases, be less suited to actual operating conditions. <\/p><p> <\/p><p>Sizing therefore enables us to strike the right balance between:<\/p><ul><li>the thermal power to be transferred<\/li><li>la surface d\u2019\u00e9change n\u00e9cessaire<\/li><li>permissible pressure drops<\/li><li>the available space<\/li><li>the materials<\/li><li>ease of maintenance<\/li><li>resistance to fouling<\/li><li>corrosion resistance<\/li><li>integration into the existing system<\/li><\/ul><p> <\/p><p>This stage is particularly important for industrial heat exchangers, finned heat exchanger banks, heat recovery units and like-for-like replacements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-2608b4d\" data-id=\"2608b4d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-aec0b63 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"aec0b63\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What data is required to size a heat exchanger?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5971f48 elementor-widget elementor-widget-text-editor\" data-id=\"5971f48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>To carry out a design study, a number of details are required. The more accurate the data provided, the more reliable the technical analysis will be. <\/p><p>The main details to be provided are:<\/p><ul><li>the nature of fluids<\/li><li>air or fluid flow rates<\/li><li>inlet temperatures<\/li><li>the desired outlet temperatures<\/li><li>the expected thermal output<\/li><li>the maximum design pressure and temperature (PS\/TS)<\/li><li>permissible pressure drops<\/li><li>the installation environment<\/li><li>the available space<\/li><li>connection constraints<\/li><li>the risk of clogging<\/li><li>the risks of corrosion<\/li><li>cleaning requirements<\/li><li>the materials requested or specified<\/li><li>specific standards or requirements<\/li><\/ul><p> <\/p><p>When replacing a heat exchanger, it is also helpful to provide a diagram, photographs, an existing part number or a set of measurements. These details enable the mechanical integration of the old equipment to be maintained whilst ensuring the required thermal performance is met. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-90b3238 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"90b3238\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-ece367a\" data-id=\"ece367a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f60ba66 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"f60ba66\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The physical principles of thermal calculation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d03afd elementor-widget elementor-widget-text-editor\" data-id=\"9d03afd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A heat exchanger relies primarily on two phenomena: convection and conduction.<\/p><p>Convection refers to the transfer of heat between a moving fluid and a wall. In industrial applications, this convection is often forced: air circulation by a fan, water circulation by a pump, or the circulation of steam, fumes or process fluids. <\/p><p>Conduction refers to the transfer of heat through the wall of the heat exchanger: a tube, plate, fin or metal surface. The material used therefore has a direct influence on the quality of the heat transfer. <\/p><p>Radiation may play a role in certain high-temperature applications, but it is often a secondary factor in standard calculations for industrial heat exchangers.<\/p><p>Dimensioning involves matching three elements:<\/p><ul><li>the thermal power to be transferred<\/li><li>the available heat transfer surface area<\/li><li>the actual conditions under which fluids flow<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16b7f6b elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"16b7f6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Calculating the thermal capacity of a heat exchanger<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15b7bb4 elementor-widget elementor-widget-text-editor\" data-id=\"15b7bb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Thermal power is the amount of energy that the heat exchanger must transfer between two fluids.<\/p><p> <\/p><p>In a simple case, it can be estimated using the formula:<\/p><p><strong>P = <\/strong><strong>\u1e41<\/strong><strong> x Cp x <\/strong><strong>\u0394<\/strong><strong>T<\/strong><\/p><p>with :<\/p><ul><li><strong>P<\/strong> : thermal power in W or kW<\/li><li><strong>\u1e41<\/strong> : mass flow rate of the fluid in kg\/s<\/li><li><strong>Cp<\/strong> : specific heat capacity of the fluid in J\/kg\u00b7K<\/li><li><strong>\u0394T<\/strong> : temperature difference between the fluid inlet and outlet, in K or \u00b0C<\/li><\/ul><p> <\/p><p>When the flow rate is expressed as a volumetric flow rate, the following can be used:<\/p><p><strong>P = \u03c1 x Qv x Cp x \u0394T<\/strong><\/p><p>with :<\/p><ul><li><strong>\u03c1<\/strong> : density of the fluid in kg\/m\u00b3<\/li><li><strong>Qv<\/strong> : volume flow rate in m\u00b3\/s<\/li><li><strong>Cp<\/strong> : specific heat capacity<\/li><li><strong>\u0394T<\/strong> : temperature difference<\/li><\/ul><p> <\/p><p>These formulas provide an initial estimate of the power to be transferred. However, they are not sufficient for the complete sizing of an industrial heat exchanger. The design team must then take into account the technology, pressure drops, heat transfer surface area, materials, fouling and operating constraints.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-0b669aa\" data-id=\"0b669aa\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ef189fd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ef189fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Choosing the right heat exchanger technology<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3321e1f elementor-widget elementor-widget-text-editor\" data-id=\"3321e1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Before finalising the calculation, you must select the heat exchanger technology best suited to your requirements.<\/p><p>An air-to-water heat exchanger is used to heat or cool a flow of air using hot water, chilled water or glycol-based water. It is commonly used in air handling units, industrial installations and finned coils. <\/p><p> <\/p><p>An air\/steam heat exchanger uses steam as the hot fluid. It is suitable for applications requiring high thermal output or a rapid rise in temperature. <\/p><p>An air\/flue gas heat exchanger is used to recover the energy contained in industrial flue gases. It must be sized taking into account the temperature and humidity of the flue gases in order to control condensation, as well as their composition, fouling, corrosion and maintenance requirements. <\/p><p>An air-to-air heat exchanger transfers heat between two air streams without them mixing directly. It can be used in energy recovery or air treatment projects. <\/p><p> <\/p><p>A finned tube coil is used to heat, cool or recover thermal energy from an air flow.<\/p><p>Its dimensions depend mainly on several factors:<\/p><ul><li>The geometry of the heat exchanger: centre-to-centre distance between tubes, length and height <\/li><li><strong>The pitch of the blades<\/strong> <\/li><li><strong>The number of rows of tubes<\/strong> <\/li><li>Materials used: tubes, fins and frame <\/li><li>Operating conditions: flow rates, inlet and outlet temperatures<\/li><\/ul><p> <\/p><p>The choice of technology has a direct impact on the heat transfer surface area, pressure drops, space requirements and maintenance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1a0313 elementor-widget elementor-widget-image\" data-id=\"f1a0313\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"448\" height=\"414\" src=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-dimmensionner-un-echangeur-thermique.png\" class=\"attachment-large size-large wp-image-16886\" alt=\"\" srcset=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-dimmensionner-un-echangeur-thermique.png 448w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-dimmensionner-un-echangeur-thermique-300x277.png 300w\" sizes=\"(max-width: 448px) 100vw, 448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-80e9631 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"80e9631\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-bd46a23\" data-id=\"bd46a23\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b9781b5 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"b9781b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Calculate the average temperature difference<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f56d12b elementor-widget elementor-widget-text-editor\" data-id=\"f56d12b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>When sizing the heat transfer surface area, it is not enough simply to consider the temperature difference at the inlet or outlet. The temperature difference between the two fluids changes along the length of the heat exchanger. <\/p><p>We therefore use the mean logarithmic temperature difference, known as DTLM or \u0394TLM.<\/p><p> <\/p><p>The formula is:<\/p><p><strong>\u0394TLM = (\u0394T1 &#8211; \u0394T2) \/ ln(\u0394T1 \/ \u0394T2)<\/strong><\/p><p>with :<\/p><ul><li><strong>\u0394T1<\/strong> : temperature difference between the two fluids at one end of the heat exchanger<\/li><li><strong>\u0394T2<\/strong> : temperature difference between the two fluids at the other end<\/li><li><strong>ln<\/strong> : natural logarithm<\/li><\/ul><p> <\/p><p>The DTLM provides an average difference that is representative of the actual heat transfer. It is used to estimate the required heat transfer surface area. <\/p><p>Please note: this approach must be adapted to suit the heat exchanger\u2019s configuration, the direction of fluid flow, any changes of state and the actual operating conditions.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ed8228 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"6ed8228\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Determine the heat transfer area<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d41bc09 elementor-widget elementor-widget-text-editor\" data-id=\"d41bc09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Once the thermal power and the DTLM are known, the required heat transfer area can be estimated.<\/p><p>The basic relationship is:<\/p><p><strong>P = K x S x <\/strong><strong>\u0394<\/strong><strong>TLM<\/strong><\/p><p>with :<\/p><ul><li><strong>P<\/strong> : heat exchange capacity<\/li><li><strong>K<\/strong> : overall heat transfer coefficient<\/li><li><strong>S<\/strong> : exchange surface<\/li><li><strong>\u0394TLM<\/strong> : mean logarithmic temperature difference<\/li><\/ul><p> <\/p><p>The exchange surface can therefore be expressed as follows:<\/p><p><strong>S = P \/ (K x \u0394TLM)<\/strong><\/p><p>This formula helps us to understand the relationship between power, heat transfer surface area and the quality of heat transfer.<\/p><p>In practice, the heat transfer area depends on the technology used: tubes, fins, plates, bundles, the number of rows, tube length, diameter, frontal area, flow velocity and the geometry of the heat exchanger.<\/p><p>For a finned heat exchanger, for example, the heat transfer surface area depends on the number of fins, the fin pitch, the tube diameter, the number of rows and the air flow.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e981a5 elementor-widget elementor-widget-image\" data-id=\"5e981a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-calculer-la-surface-echange-1-1024x1024.png\" class=\"attachment-large size-large wp-image-16887\" alt=\"\" srcset=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-calculer-la-surface-echange-1-1024x1024.png 1024w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-calculer-la-surface-echange-1-300x300.png 300w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-calculer-la-surface-echange-1-150x150.png 150w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-calculer-la-surface-echange-1-768x768.png 768w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/comment-calculer-la-surface-echange-1.png 1254w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-23c361a\" data-id=\"23c361a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-87b8360 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"87b8360\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Understanding the overall heat transfer coefficient<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aceff48 elementor-widget elementor-widget-text-editor\" data-id=\"aceff48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The overall heat transfer coefficient, often denoted by K or U, represents the heat exchanger\u2019s ability to transfer heat between two fluids<\/p><p> <\/p><p>It depends, in particular, on:<\/p><ul><li>convection coefficients on the hot-fluid side and on the cold-fluid side<\/li><li>the thermal conductivity of the wall<\/li><li>the wall thickness<\/li><li>the materials used<\/li><li>traffic speeds<\/li><li>the geometry of the heat exchanger<\/li><li>of the flow regime<\/li><li>clogging<\/li><li>of the surface finish<\/li><\/ul><p> <\/p><p>A simplified expression for the overall thermal resistance can be written as follows:<\/p><p><strong>1 \/ K = 1 \/ h1 + e \/ \u03bb + 1 \/ h2 + Rf<\/strong><\/p><p>with :<\/p><ul><li><strong>h1<\/strong> : convective heat transfer coefficient on fluid side 1<\/li><li><strong>h2<\/strong> : convective heat transfer coefficient on fluid side 2<\/li><li><strong>e<\/strong> : wall thickness<\/li><li><strong>\u03bb<\/strong> : thermal conductivity of the material<\/li><li><strong>Rf<\/strong> : fouling-induced resistance<\/li><\/ul><p> <\/p><p>This formula provides a simplified view. In industrial design, the actual calculation of the overall heat transfer coefficient depends on numerous parameters: the physical properties of the fluids, flow velocities, geometry, materials, fouling conditions and operating constraints. <\/p><p>Internal calculation and selection methods are therefore not limited to a single formula. They require a comprehensive technical analysis. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24441f6 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"24441f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Check for pressure drops<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b577523 elementor-widget elementor-widget-text-editor\" data-id=\"b577523\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pressure drops correspond to the resistance encountered by fluids as they flow through the heat exchanger. They are expressed as a pressure difference. <\/p><p> <\/p><p>They may come from:<\/p><ul><li>friction along the walls<\/li><li>changes in direction<\/li><li>connections<\/li><li>changes in cross-section<\/li><li>flow through the fins<\/li><li>internal geometry<\/li><li>due to gradual build-up of dirt<\/li><\/ul><p> <\/p><p>A general formula used in fluid mechanics is:<\/p><p><strong>\u0394P = f x (L \/ D) x (\u03c1 x v\u00b2 \/ 2) + \u03a3\u03b6 x (\u03c1 x v\u00b2 \/ 2)<\/strong><\/p><p> <\/p><p>with :<\/p><ul><li><strong>\u0394P<\/strong> : pressure drop<\/li><li><strong>f<\/strong> : coefficient of friction<\/li><li><strong>L<\/strong> : passage length<\/li><li><strong>D<\/strong> : hydraulic diameter<\/li><li><strong>\u03c1<\/strong> : density of the fluid<\/li><li><strong>v<\/strong> : fluid velocity<\/li><li><strong>\u03a3\u03b6<\/strong> : sum of the singular loss coefficients<\/li><\/ul><p> <\/p><p>This formula provides a basis for understanding. In a heat exchanger, the actual pressure drops depend on the technology, the geometry, the flow velocities, the fluids and the degree of fouling taken into account. <\/p><p> <\/p><p>This step is essential, particularly in projects involving a like-for-like replacement. The new heat exchanger must remain compatible with the existing fans, pumps, ducts, and hydraulic or steam systems. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-45a42a3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"45a42a3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-60c858b\" data-id=\"60c858b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3cfb7b0 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"3cfb7b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Take fouling into account<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d24362 elementor-widget elementor-widget-text-editor\" data-id=\"7d24362\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fouling creates additional resistance to heat transfer. It can reduce the heat exchanger\u2019s performance, increase pressure drops and lead to more frequent maintenance. <\/p><p> <\/p><p>The risk of fouling depends, in particular, on:<\/p><ul><li>the nature of fluids<\/li><li>the presence of dust or particles<\/li><li>water quality<\/li><li>the presence of condensate<\/li><li>fumes<\/li><li>contaminated fluids<\/li><li>temperature<\/li><li>of the feed rate<\/li><li>from accessibility to cleaning<\/li><\/ul><p> <\/p><p>In a finned coil, the fin pitch is an important parameter. A pitch that is too narrow may encourage the build-up of dust in a dusty environment. A wider pitch may make cleaning easier and limit the increase in pressure drop over time.  <\/p><p>Fouling must therefore be taken into account right from the design stage, without waiting for the first signs of a decline in performance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b494b19 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"b494b19\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Incorporating corrosion and surface treatments<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b47af7 elementor-widget elementor-widget-text-editor\" data-id=\"2b47af7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In certain environments, corrosion can significantly reduce the service life of a heat exchanger. This is the case in humid, saline or chemical environments, or where the fluids are corrosive. <\/p><p>The choice of materials and surface treatments must therefore be carefully considered.<\/p><p> <\/p><p>According to the project, several parameters can be analysed:<\/p><ul><li>nature of the fluids<\/li><li>operating temperature<\/li><li>humidity<\/li><li>presence of chemical agents<\/li><li>outdoor exhibition<\/li><li>presence of salt air<\/li><li>cleaning frequency<\/li><li>maintenance requirements<\/li><li>expected lifespan<\/li><\/ul><p> <\/p><p>A surface treatment may be considered to improve corrosion resistance, but it must remain compatible with the expected temperatures, materials, mechanical stresses and thermal performance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-465fa14\" data-id=\"465fa14\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d4dc8cd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"d4dc8cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Is it possible to size a heat exchanger without all the data?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72a6ff2 elementor-widget elementor-widget-text-editor\" data-id=\"72a6ff2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>An initial analysis can be carried out using partial data, but a reliable design requires a minimum amount of technical information.<\/p><p> <\/p><p>The priority data are:<\/p><ul><li>fluids<\/li><li>flow rates<\/li><li>the inlet and outlet temperatures<\/li><li>operating pressure<\/li><li>the required power<\/li><li>permissible pressure drops<\/li><li>the installation environment<\/li><li>the available space<\/li><\/ul><p> <\/p><p>In the case of a replacement, a diagram, photographs, an old heat exchanger or a set of measurements may help to reconstruct the mechanical constraints. However, operating data is still required to validate the thermal performance. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-341f7ea elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"341f7ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:150}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0190bbe elementor-widget elementor-widget-text-editor\" data-id=\"0190bbe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Trianon \u00c9changeur supports manufacturers, installers, operators and engineering firms in the calculation and design of bespoke heat exchangers.<\/p><p>The design office analyses the project data to devise a suitable solution:<\/p><ul><li>fin-type heat exchanger<\/li><li>Hot water coil<\/li><li>cold battery<\/li><li>steam generator<\/li><li>air-to-water heat exchanger<\/li><li>air-vapour heat exchanger<\/li><li>air-to-flue gas heat exchanger<\/li><li>air-to-air heat exchanger<\/li><li>Heat recovery unit <\/li><li>replacement heat exchanger<\/li><li>industrial heat recovery solution<\/li><\/ul><p>The study takes into account thermal performance, pressure drops, materials, space constraints, connections, the environment, fouling, corrosion and maintenance.<\/p><p>The aim is to propose a heat exchanger that is consistent with the existing installation, the energy performance targets and the actual operating conditions. <\/p><p class=\"MsoNormal\" style=\"margin-bottom: 0cm\"><b><span style=\"font-size: 10.0pt;line-height: 107%\">Need to size a heat exchanger?<\/span><\/b><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa10997 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"fa10997\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.trianon-echangeur.com\/en\/quotation-request\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ask for a quote<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-53672f4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"53672f4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0bdb3db\" data-id=\"0bdb3db\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d1b1ef7 elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"d1b1ef7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:150}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef8dce0 elementor-widget elementor-widget-toggle\" data-id=\"ef8dce0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2511\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2511\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Which formula should be used to calculate the power of a heat exchanger?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2511\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2511\"><p>The basic formula is P = \u1e41 \u00d7 Cp \u00d7 \u0394T. It relates thermal power to the mass flow rate, the specific heat capacity of the fluid and the temperature difference. It provides an initial estimate, but industrial design work then requires verification of the heat transfer surface area, pressure drops, materials and operating constraints.  <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2512\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2512\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">What is the purpose of the DTLM when sizing a heat exchanger?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2512\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2512\"><p>The DTLM, or average logarithmic temperature difference, is used to assess the average temperature difference between the two fluids over the entire length of the heat exchanger. It is used to estimate the required heat transfer area. <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2513\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2513\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Why are pressure drops important?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2513\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2513\"><p>Pressure drops affect the operation of pumps, fans and associated systems. If they are too high, they can reduce flow rate, increase energy consumption and impair the system\u2019s performance. <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2514\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2514\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Does the sizing take fouling into account?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2514\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2514\"><p>Yes. Fouling must be taken into account right from the design stage, as it can reduce heat transfer and increase pressure drops. It can influence the choice of fin pitch, materials, surface treatment and ease of cleaning.  <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2515\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2515\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Can a heat exchanger be recalculated when it is being replaced?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2515\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2515\"><p>Yes. A like-for-like replacement can retain the dimensions, connections and installation constraints of the old heat exchanger, whilst allowing the thermal performance to be checked or adjusted in line with current operating conditions. <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Which formula should be used to calculate the power of a heat exchanger?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>The basic formula is P = \\u1e41 \\u00d7 Cp \\u00d7 \\u0394T. It relates thermal power to the mass flow rate, the specific heat capacity of the fluid and the temperature difference. It provides an initial estimate, but industrial design work then requires verification of the heat transfer surface area, pressure drops, materials and operating constraints.  <\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"What is the purpose of the DTLM when sizing a heat exchanger?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>The DTLM, or average logarithmic temperature difference, is used to assess the average temperature difference between the two fluids over the entire length of the heat exchanger. It is used to estimate the required heat transfer area. <\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"Why are pressure drops important?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>Pressure drops affect the operation of pumps, fans and associated systems. If they are too high, they can reduce flow rate, increase energy consumption and impair the system\\u2019s performance. <\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"Does the sizing take fouling into account?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>Yes. Fouling must be taken into account right from the design stage, as it can reduce heat transfer and increase pressure drops. It can influence the choice of fin pitch, materials, surface treatment and ease of cleaning.  <\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"Can a heat exchanger be recalculated when it is being replaced?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>Yes. A like-for-like replacement can retain the dimensions, connections and installation constraints of the old heat exchanger, whilst allowing the thermal performance to be checked or adjusted in line with current operating conditions. <\\\/p>\\n\"}}]}<\/script>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div> \n","protected":false},"excerpt":{"rendered":"<p>FAQ &#8211; Heat exchangers How do you size a heat exchanger? How do you size a heat exchanger? The design of a heat exchanger involves defining a solution capable of transferring thermal power between two fluids under specific operating conditions. It is not simply a matter of selecting equipment based on its dimensions: it is [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"class_list":["post-16890","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How do you size a heat exchanger? | TRIANON ECHANGEUR<\/title>\n<meta name=\"description\" content=\"D\u00e9couvrez comment dimensionner un \u00e9changeur thermique industriel : fluides, temp\u00e9ratures, d\u00e9bits, puissance, surface d\u2019\u00e9change, pertes de charge et contraintes d\u2019exploitation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How do you size a heat exchanger? | TRIANON ECHANGEUR\" \/>\n<meta property=\"og:description\" content=\"D\u00e9couvrez comment dimensionner un \u00e9changeur thermique industriel : fluides, temp\u00e9ratures, d\u00e9bits, puissance, surface d\u2019\u00e9change, pertes de charge et contraintes d\u2019exploitation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/\" \/>\n<meta property=\"og:site_name\" content=\"TRIANON ECHANGEUR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/fr-fr.facebook.com\/TrianonEchangeur\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-20T08:08:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/dimmensionner-un-echangeur-thermique.png\" \/>\n\t<meta property=\"og:image:width\" content=\"550\" \/>\n\t<meta property=\"og:image:height\" content=\"402\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-do-you-size-a-heat-exchanger\\\/\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-do-you-size-a-heat-exchanger\\\/\",\"name\":\"How do you size a heat exchanger? | TRIANON ECHANGEUR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-do-you-size-a-heat-exchanger\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-do-you-size-a-heat-exchanger\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/dimmensionner-un-echangeur-thermique.png\",\"datePublished\":\"2026-08-19T07:59:18+00:00\",\"dateModified\":\"2026-08-20T08:08:46+00:00\",\"description\":\"D\u00e9couvrez comment dimensionner un \u00e9changeur thermique industriel : fluides, temp\u00e9ratures, d\u00e9bits, puissance, surface d\u2019\u00e9change, pertes de charge et contraintes d\u2019exploitation.\",\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-do-you-size-a-heat-exchanger\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-do-you-size-a-heat-exchanger\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/dimmensionner-un-echangeur-thermique.png\",\"contentUrl\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/dimmensionner-un-echangeur-thermique.png\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/\",\"name\":\"TRIANON ECHANGEUR\",\"description\":\"Fabricant d&#039;\u00e9changeurs thermiques et de r\u00e9cup\u00e9rateurs de chaleur.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#organization\",\"name\":\"TRIANON ECHANGEUR\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/trianon-echangeur-2.png\",\"contentUrl\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/trianon-echangeur-2.png\",\"width\":881,\"height\":205,\"caption\":\"TRIANON ECHANGEUR\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/fr-fr.facebook.com\\\/TrianonEchangeur\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/trianon-echangeur\\\/\",\"https:\\\/\\\/www.wikidata.org\\\/wiki\\\/Q139927450\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How do you size a heat exchanger? | TRIANON ECHANGEUR","description":"D\u00e9couvrez comment dimensionner un \u00e9changeur thermique industriel : fluides, temp\u00e9ratures, d\u00e9bits, puissance, surface d\u2019\u00e9change, pertes de charge et contraintes d\u2019exploitation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/","og_locale":"en_GB","og_type":"article","og_title":"How do you size a heat exchanger? | TRIANON ECHANGEUR","og_description":"D\u00e9couvrez comment dimensionner un \u00e9changeur thermique industriel : fluides, temp\u00e9ratures, d\u00e9bits, puissance, surface d\u2019\u00e9change, pertes de charge et contraintes d\u2019exploitation.","og_url":"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/","og_site_name":"TRIANON ECHANGEUR","article_publisher":"https:\/\/fr-fr.facebook.com\/TrianonEchangeur\/","article_modified_time":"2026-08-20T08:08:46+00:00","og_image":[{"width":550,"height":402,"url":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/dimmensionner-un-echangeur-thermique.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/","url":"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/","name":"How do you size a heat exchanger? | TRIANON ECHANGEUR","isPartOf":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/#primaryimage"},"image":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/#primaryimage"},"thumbnailUrl":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/dimmensionner-un-echangeur-thermique.png","datePublished":"2026-08-19T07:59:18+00:00","dateModified":"2026-08-20T08:08:46+00:00","description":"D\u00e9couvrez comment dimensionner un \u00e9changeur thermique industriel : fluides, temp\u00e9ratures, d\u00e9bits, puissance, surface d\u2019\u00e9change, pertes de charge et contraintes d\u2019exploitation.","inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.trianon-echangeur.com\/en\/how-do-you-size-a-heat-exchanger\/#primaryimage","url":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/dimmensionner-un-echangeur-thermique.png","contentUrl":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/dimmensionner-un-echangeur-thermique.png"},{"@type":"WebSite","@id":"https:\/\/www.trianon-echangeur.com\/en\/#website","url":"https:\/\/www.trianon-echangeur.com\/en\/","name":"TRIANON ECHANGEUR","description":"Fabricant d&#039;\u00e9changeurs thermiques et de r\u00e9cup\u00e9rateurs de chaleur.","publisher":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.trianon-echangeur.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.trianon-echangeur.com\/en\/#organization","name":"TRIANON ECHANGEUR","url":"https:\/\/www.trianon-echangeur.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.trianon-echangeur.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2023\/05\/trianon-echangeur-2.png","contentUrl":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2023\/05\/trianon-echangeur-2.png","width":881,"height":205,"caption":"TRIANON ECHANGEUR"},"image":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/fr-fr.facebook.com\/TrianonEchangeur\/","https:\/\/www.linkedin.com\/company\/trianon-echangeur\/","https:\/\/www.wikidata.org\/wiki\/Q139927450"]}]}},"_links":{"self":[{"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/pages\/16890","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/comments?post=16890"}],"version-history":[{"count":2,"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/pages\/16890\/revisions"}],"predecessor-version":[{"id":16892,"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/pages\/16890\/revisions\/16892"}],"wp:attachment":[{"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/media?parent=16890"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}