{"id":16895,"date":"2026-08-14T10:30:34","date_gmt":"2026-08-14T08:30:34","guid":{"rendered":"https:\/\/www.trianon-echangeur.com\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/"},"modified":"2026-08-20T11:23:19","modified_gmt":"2026-08-20T09:23:19","slug":"how-can-you-prevent-a-heat-exchanger-from-becoming-clogged","status":"publish","type":"page","link":"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/","title":{"rendered":"How can you prevent a heat exchanger from becoming clogged?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"16895\" class=\"elementor elementor-16895 elementor-16707\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ab259f6 elementor-section-height-min-height elementor-section-boxed elementor-section-height-default elementor-section-items-middle\" data-id=\"ab259f6\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ae71777\" data-id=\"ae71777\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-499cf57 elementor-widget elementor-widget-text-editor\" data-id=\"499cf57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>FAQ &#8211; Heat exchangers<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd2da20 elementor-widget elementor-widget-heading\" data-id=\"fd2da20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">How can you prevent a heat exchanger from becoming clogged?<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1038d40 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1038d40\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-b7aa209\" data-id=\"b7aa209\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c47662c elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"c47662c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Heat exchanger fouling: causes, risks and solutions<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b4ccbe elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"7b4ccbe\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:150}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f668cb7 elementor-widget elementor-widget-text-editor\" data-id=\"f668cb7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fouling of a heat exchanger is one of the main causes of performance loss in an industrial plant. It reduces the efficiency of heat transfer, increases pressure drops and can lead to excessive energy consumption, more frequent maintenance or a production shutdown. <\/p><p>In industrial applications, fouling affects heat exchangers, finned coils, heat recovery units and equipment used with air, water, steam, flue gases or process fluids. The extent of fouling depends on the fluids used, operating conditions, temperature, flow velocity, the environment and the design of the equipment. <\/p><p>At Trianon \u00c9changeur, each project is assessed in light of the actual constraints of the installation in order to propose a heat exchanger that is suited to the process, the environment and the energy efficiency targets.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-16a3281\" data-id=\"16a3281\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a3117cb elementor-widget elementor-widget-image\" data-id=\"a3117cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-1024x768.jpg\" class=\"attachment-large size-large wp-image-16893\" alt=\"\" srcset=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-1024x768.jpg 1024w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-300x225.jpg 300w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-768x576.jpg 768w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-1536x1152.jpg 1536w, https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-2048x1536.jpg 2048w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7dafe4c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7dafe4c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-d38c759\" data-id=\"d38c759\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-31bab8d elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"31bab8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What is fouling in a heat exchanger?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33b20e2 elementor-widget elementor-widget-text-editor\" data-id=\"33b20e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fouling in a heat exchanger refers to the gradual build-up of deposits on the heat transfer surfaces. These deposits create a barrier between the fluids and the walls of the exchanger, thereby limiting heat transfer. A fouled heat exchanger is therefore forced to operate under less favourable conditions. Thermal output decreases, pressure drops increase, and the system may consume more energy to achieve the same result. In some cases, fouling can also accelerate corrosion, make cleaning more difficult or reduce the equipment\u2019s service life.    <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a023fb5 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"a023fb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What are the implications for industrial performance?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6200925 elementor-widget elementor-widget-text-editor\" data-id=\"6200925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A fouled heat exchanger gradually loses efficiency. Heat is transferred less effectively between the fluids, which can lead to a drop in temperature on the air or fluid side, insufficient thermal output or a decline in process performance. Fouling can also increase pressure drops. Fans, pumps or associated equipment must then work harder to maintain the desired flow rate. This can lead to increased energy consumption and greater strain on the system.    <\/p><p>The main consequences are:<\/p><ul><li>decrease in thermal efficiency<\/li><li>increase in pressure drops<\/li><li>excessive energy consumption<\/li><li>more frequent maintenance<\/li><li>risk of accelerated corrosion<\/li><li>loss of cooling or heating capacity<\/li><li>production stoppage in the event of severe blockage<\/li><li>early replacement of the heat exchanger<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-2608b4d\" data-id=\"2608b4d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-aec0b63 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"aec0b63\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What are the main types of fouling?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5971f48 elementor-widget elementor-widget-text-editor\" data-id=\"5971f48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fouling can take various forms depending on the fluids and the operating environment.<\/p><ul><li><span style=\"color: #c1003c\"><em><strong>Particulate fouling<\/strong><\/em><\/span><\/li><\/ul><p>It is caused by the build-up of dust, fibres, particles or solid deposits. It is common in industrial ventilation systems, air handling units, processes involving contaminated air, or dusty environments. <\/p><p>In a finned heat exchanger, particulate build-up can gradually obstruct the airflow and significantly reduce thermal performance.<\/p><ul><li><em><span style=\"color: #c1003c\"><strong>Corrosion-induced fouling<\/strong><\/span><\/em><\/li><\/ul><p>Corrosion can lead to the formation of deposits, oxides or surface damage. It occurs in particular when materials are unsuitable for the environment, humidity, chemical agents or the nature of the fluids. <\/p><p>In this case, the choice of materials and surface treatments becomes crucial.<\/p><ul><li><span style=\"color: #c1003c\"><em><strong>Biological fouling<\/strong><\/em><\/span><\/li><\/ul><p>It may occur in certain systems that use water or fluids conducive to biological growth. It can cause deposits to form, restrict the flow of fluid and impair the heat exchanger\u2019s performance. <\/p><ul><li><span style=\"color: #c1003c\"><em><strong>Chemical fouling<\/strong><\/em><\/span><\/li><\/ul><p>Certain fluids can cause reactions or deposits on heat exchange surfaces. <\/p><p>This phenomenon depends on the fluid&#8217;s composition, temperature, operating time, and flow conditions.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-90b3238 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"90b3238\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-ece367a\" data-id=\"ece367a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f60ba66 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"f60ba66\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How can you minimize fouling in a heat exchanger?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d03afd elementor-widget elementor-widget-text-editor\" data-id=\"9d03afd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fouling control begins as early as the design phase. A heat exchanger must be selected and sized based on the fluids, temperatures, flow rates, cleaning requirements, and installation environment. <\/p><p>There are several ways to reduce the risk of clogging.<\/p><ul><li><span style=\"color: #c1003c\"><em><strong>Adapting heat exchanger technology<\/strong><\/em><\/span><\/li><\/ul><p>The choice of technology depends on the type of fluid, the presence of particles, the humidity level, temperatures, and ease of access for maintenance.<\/p><p>A finned coil, an air-to-air heat exchanger, a flue gas heat recovery unit, or a fluid-to-fluid heat exchanger are not subject to the same fouling constraints. The choice must therefore be based on the actual process, and not solely on the required thermal capacity. <\/p><ul><li><em><span style=\"color: #c1003c\"><strong>Choosing the Right Fin Pitch<\/strong><\/span><\/em><\/li><\/ul><p>In a finned heat exchanger, the fin pitch plays an important role. A pitch that is too tight can promote the accumulation of dust or deposits in a contaminated environment. <\/p><p>In applications exposed to dust, fibers, or particles, a wider fin spacing can facilitate airflow and make it easier to maintain the equipment.<\/p><ul><li><span style=\"color: #c1003c\"><em><strong>Plan for ease of cleaning<\/strong><\/em><\/span><\/li><\/ul><p>A heat exchanger that is difficult to clean becomes clogged more quickly over time. Access to heat exchange surfaces, filters, condensate pans, and retention areas must be taken into account during the design phase. <\/p><p>In some cases, a custom design allows for adjustments to the frame, connections, access hatches, or layout to facilitate maintenance.<\/p><ul><li><span style=\"color: #c1003c\"><em><strong>Selecting the Right Materials<\/strong><\/em><\/span><\/li><\/ul><p>The materials must be compatible with fluids, moisture, temperatures and the environment. Stainless steel, copper, aluminium or certain alloys may be considered, depending on the project\u2019s requirements. <\/p><p>In corrosive environments, surface treatment may also be considered to improve the heat exchanger\u2019s resistance.<\/p><ul><li><span style=\"color: #c1003c\"><em><strong>Introduce a regular maintenance programme<\/strong><\/em><\/span><\/li><\/ul><p>Even a well-designed heat exchanger must be inspected regularly. The frequency of cleaning depends on the environment, the level of pollution, the nature of the fluids and the rate of operation. <\/p><p>Monitoring temperatures, pressure drops and thermal performance enables any drift caused by fouling to be identified more quickly.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-0b669aa\" data-id=\"0b669aa\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ef189fd elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"ef189fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The role of sizing in fouling<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3321e1f elementor-widget elementor-widget-text-editor\" data-id=\"3321e1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Incorrect sizing can lead to fouling in a heat exchanger. An inappropriate flow velocity, an incorrectly calculated heat transfer surface area or an excessively high pressure drop can impair the system\u2019s performance. <\/p><p>The design must take into account:<\/p><ul><li>air or fluid flow rates<\/li><li>the inlet and outlet temperatures<\/li><li>the expected thermal output<\/li><li>permissible pressure drops<\/li><li>the nature of fluids<\/li><li>the expected level of fouling<\/li><li>cleaning requirements<\/li><li>the available space<\/li><li>the necessary materials and treatments<\/li><\/ul><p>At Trianon \u00c9changeur, the design department analyses these parameters to design a heat exchanger suited to the operating conditions. The aim is to ensure thermal performance whilst taking into account maintenance, durability and integration requirements. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c8a49b elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"2c8a49b\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:100}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">When should a fouled heat exchanger be cleaned or replaced?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-472d2bd elementor-widget elementor-widget-text-editor\" data-id=\"472d2bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cleaning may be sufficient where the fouling remains accessible and the heat exchanger retains its mechanical integrity. However, replacement may become necessary where the equipment shows a significant loss of performance, advanced corrosion, damaged tubes, severely degraded fins, or where effective cleaning is not possible. <\/p><p>The signs to look out for are:<\/p><ul><li>drop in outlet temperature<\/li><li>difficulty in achieving the expected performance<\/li><li>increase in pressure drops<\/li><li>increase in energy consumption<\/li><li>unusual noise or strain on the fans or pumps<\/li><li>presence of corrosion<\/li><li>leak in a pipe or manifold<\/li><li>Recurring blockages despite cleaning<\/li><\/ul><p>In the event of a replacement, Trianon \u00c9changeur can design a bespoke heat exchanger based on an existing drawing, a model to be replaced, or measurements taken on site.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa10997 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"fa10997\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.trianon-echangeur.com\/en\/quotation-request\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ask for a quote<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-301882e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"301882e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-b181f14\" data-id=\"b181f14\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f1a0313 elementor-widget elementor-widget-image\" data-id=\"f1a0313\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-solutions-scaled.jpg\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-4f2cad0\" data-id=\"4f2cad0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-341f7ea elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"341f7ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:150}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-560b096 elementor-widget elementor-widget-text-editor\" data-id=\"560b096\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Trianon \u00c9changeur supports manufacturers, installers, operators and engineering firms in the selection, sizing and replacement of industrial heat exchangers.<\/p><p>Our solutions are tailored to the specific requirements of each application: air, water, steam, flue gases, process fluids, corrosive environments, space constraints, like-for-like replacement or heat recovery.<\/p><p>An analysis of the risk of fouling is one of the factors to be taken into account when designing a high-performance, durable heat exchanger. Depending on your installation, we can advise you on the most suitable technology, a specific fin pitch, a more appropriate material, a surface treatment or a design that facilitates maintenance. <\/p><p> <\/p><p><strong>Do you need a heat exchanger suitable for a high-contamination environment?<\/strong><\/p><p>Have you noticed a drop in performance, recurring blockages or difficulty cleaning your system?<\/p><p>Please contact our design department to discuss your requirements and explore a heat exchange solution tailored to your operational constraints.<\/p><p> <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-53672f4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"53672f4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0bdb3db\" data-id=\"0bdb3db\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d1b1ef7 elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"d1b1ef7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:150}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef8dce0 elementor-widget elementor-widget-toggle\" data-id=\"ef8dce0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2511\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2511\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">How can you tell if a heat exchanger is clogged?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2511\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2511\"><p>A heat exchanger may be fouled if its performance declines, if pressure drops increase, or if the system consumes more energy to achieve the same result. A drop in temperature, insufficient flow rate or the need for increasingly frequent cleaning may also be signs of fouling. <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2512\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2512\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">L\u2019encrassement peut-il r\u00e9duire la dur\u00e9e de vie d\u2019un \u00e9changeur ?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2512\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2512\"><p>Yes. Fouling can promote corrosion, increase operating stresses and make maintenance more difficult. If deposits are not dealt with, they can reduce the service life of the heat exchanger.  <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2513\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2513\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">What type of heat exchanger should you choose to minimise fouling?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2513\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2513\"><p>The choice depends on the fluids, temperatures, flow rates, the environment and the nature of the deposits expected. In some cases, it is advisable to opt for a wider fin pitch, specific materials, a surface treatment or a design that facilitates cleaning. <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2514\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2514\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Can a fouled heat exchanger be replaced with an identical one?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2514\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2514\"><p>Yes. If the existing heat exchanger is too fouled, corroded or difficult to clean, it can be replaced with an identical unit or adapted to better meet the current requirements of the installation. Trianon \u00c9changeur can work from a drawing, an old heat exchanger or a set of dimensions.  <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2515\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2515\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewBox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewBox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">How can you prevent a finned heat exchanger from becoming clogged?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2515\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2515\"><p>To minimise fouling in a finned heat exchanger, it is necessary to select a suitable fin pitch, maintain effective upstream filtration, ensure access for cleaning, and choose materials that are compatible with the operating environment. The design must also take into account actual operating conditions. <\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How can you tell if a heat exchanger is clogged?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>A heat exchanger may be fouled if its performance declines, if pressure drops increase, or if the system consumes more energy to achieve the same result. A drop in temperature, insufficient flow rate or the need for increasingly frequent cleaning may also be signs of fouling. <\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"L\\u2019encrassement peut-il r\\u00e9duire la dur\\u00e9e de vie d\\u2019un \\u00e9changeur ?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>Yes. Fouling can promote corrosion, increase operating stresses and make maintenance more difficult. If deposits are not dealt with, they can reduce the service life of the heat exchanger.  <\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"What type of heat exchanger should you choose to minimise fouling?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>The choice depends on the fluids, temperatures, flow rates, the environment and the nature of the deposits expected. In some cases, it is advisable to opt for a wider fin pitch, specific materials, a surface treatment or a design that facilitates cleaning. <\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"Can a fouled heat exchanger be replaced with an identical one?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>Yes. If the existing heat exchanger is too fouled, corroded or difficult to clean, it can be replaced with an identical unit or adapted to better meet the current requirements of the installation. Trianon \\u00c9changeur can work from a drawing, an old heat exchanger or a set of dimensions.  <\\\/p>\\n\"}},{\"@type\":\"Question\",\"name\":\"How can you prevent a finned heat exchanger from becoming clogged?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"<p>To minimise fouling in a finned heat exchanger, it is necessary to select a suitable fin pitch, maintain effective upstream filtration, ensure access for cleaning, and choose materials that are compatible with the operating environment. The design must also take into account actual operating conditions. <\\\/p>\\n\"}}]}<\/script>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div> \n","protected":false},"excerpt":{"rendered":"<p>FAQ &#8211; Heat exchangers How can you prevent a heat exchanger from becoming clogged? Heat exchanger fouling: causes, risks and solutions Fouling of a heat exchanger is one of the main causes of performance loss in an industrial plant. It reduces the efficiency of heat transfer, increases pressure drops and can lead to excessive energy [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"class_list":["post-16895","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How can you prevent a heat exchanger from becoming clogged? | TRIANON ECHANGEUR<\/title>\n<meta name=\"description\" content=\"Understanding the causes of fouling in an industrial heat exchanger, its impact on performance, and solutions to minimise efficiency losses.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How can you prevent a heat exchanger from becoming clogged? | TRIANON ECHANGEUR\" \/>\n<meta property=\"og:description\" content=\"Understanding the causes of fouling in an industrial heat exchanger, its impact on performance, and solutions to minimise efficiency losses.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/\" \/>\n<meta property=\"og:site_name\" content=\"TRIANON ECHANGEUR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/fr-fr.facebook.com\/TrianonEchangeur\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-20T09:23:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\\\/\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\\\/\",\"name\":\"How can you prevent a heat exchanger from becoming clogged? | TRIANON ECHANGEUR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/encrassement-echangeur-thermique-1024x768.jpg\",\"datePublished\":\"2026-08-14T08:30:34+00:00\",\"dateModified\":\"2026-08-20T09:23:19+00:00\",\"description\":\"Understanding the causes of fouling in an industrial heat exchanger, its impact on performance, and solutions to minimise efficiency losses.\",\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/encrassement-echangeur-thermique-1024x768.jpg\",\"contentUrl\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/encrassement-echangeur-thermique-1024x768.jpg\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/\",\"name\":\"TRIANON ECHANGEUR\",\"description\":\"Fabricant d&#039;\u00e9changeurs thermiques et de r\u00e9cup\u00e9rateurs de chaleur.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#organization\",\"name\":\"TRIANON ECHANGEUR\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/trianon-echangeur-2.png\",\"contentUrl\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/trianon-echangeur-2.png\",\"width\":881,\"height\":205,\"caption\":\"TRIANON ECHANGEUR\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trianon-echangeur.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/fr-fr.facebook.com\\\/TrianonEchangeur\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/trianon-echangeur\\\/\",\"https:\\\/\\\/www.wikidata.org\\\/wiki\\\/Q139927450\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How can you prevent a heat exchanger from becoming clogged? | TRIANON ECHANGEUR","description":"Understanding the causes of fouling in an industrial heat exchanger, its impact on performance, and solutions to minimise efficiency losses.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/","og_locale":"en_GB","og_type":"article","og_title":"How can you prevent a heat exchanger from becoming clogged? | TRIANON ECHANGEUR","og_description":"Understanding the causes of fouling in an industrial heat exchanger, its impact on performance, and solutions to minimise efficiency losses.","og_url":"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/","og_site_name":"TRIANON ECHANGEUR","article_publisher":"https:\/\/fr-fr.facebook.com\/TrianonEchangeur\/","article_modified_time":"2026-08-20T09:23:19+00:00","og_image":[{"width":2560,"height":1920,"url":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-scaled.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/","url":"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/","name":"How can you prevent a heat exchanger from becoming clogged? | TRIANON ECHANGEUR","isPartOf":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/#primaryimage"},"image":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/#primaryimage"},"thumbnailUrl":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-1024x768.jpg","datePublished":"2026-08-14T08:30:34+00:00","dateModified":"2026-08-20T09:23:19+00:00","description":"Understanding the causes of fouling in an industrial heat exchanger, its impact on performance, and solutions to minimise efficiency losses.","inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.trianon-echangeur.com\/en\/how-can-you-prevent-a-heat-exchanger-from-becoming-clogged\/#primaryimage","url":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-1024x768.jpg","contentUrl":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2026\/08\/encrassement-echangeur-thermique-1024x768.jpg"},{"@type":"WebSite","@id":"https:\/\/www.trianon-echangeur.com\/en\/#website","url":"https:\/\/www.trianon-echangeur.com\/en\/","name":"TRIANON ECHANGEUR","description":"Fabricant d&#039;\u00e9changeurs thermiques et de r\u00e9cup\u00e9rateurs de chaleur.","publisher":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.trianon-echangeur.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.trianon-echangeur.com\/en\/#organization","name":"TRIANON ECHANGEUR","url":"https:\/\/www.trianon-echangeur.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.trianon-echangeur.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2023\/05\/trianon-echangeur-2.png","contentUrl":"https:\/\/www.trianon-echangeur.com\/wp-content\/uploads\/2023\/05\/trianon-echangeur-2.png","width":881,"height":205,"caption":"TRIANON ECHANGEUR"},"image":{"@id":"https:\/\/www.trianon-echangeur.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/fr-fr.facebook.com\/TrianonEchangeur\/","https:\/\/www.linkedin.com\/company\/trianon-echangeur\/","https:\/\/www.wikidata.org\/wiki\/Q139927450"]}]}},"_links":{"self":[{"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/pages\/16895","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/comments?post=16895"}],"version-history":[{"count":2,"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/pages\/16895\/revisions"}],"predecessor-version":[{"id":16897,"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/pages\/16895\/revisions\/16897"}],"wp:attachment":[{"href":"https:\/\/www.trianon-echangeur.com\/en\/wp-json\/wp\/v2\/media?parent=16895"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}