Customized, adaptable & varied – Our plate heat exchangers for data centers

Plate heat exchangers for data centers

Our plate heat exchangers for data centers

echangeur à plaque pour data center

Aluminium cross-flow heat exchangers with hydrophobic treatment for Data Center applications.
The number and size of Data Centers is growing rapidly worldwide, and it is essential to optimize their cooling performance. Our air-air plate heat exchangers are at the heart of this system, designed with cross-flow air-air plates for indirect, adiabatic evaporative cooling in the Data Center environment.

The arrangement allows air to circulate in a closed loop: the primary air is extracted from the Data Center, cooled by the heat exchanger in adiabatic mode and returned to the system.

The geometry of the Plates ensures excellent surface water distribution. A surface treatment (blue color) improves the hydroscopic qualities of the aluminum plate and increases its wettability. This increases heat exchange efficiency and reduces water consumption.

Plates heat exchangers for data centers

What are the advantages of plate heat exchangers for data centers?

Design

Our custom-built heat exchangers for data centers are dimensioned to provide the best thermal efficiency to meet the most stringent technical constraints.

BENEFITS :
- High-efficiency counter-current heat exchanger with efficiency of over 73% and up to 90%.
- Use of latent heat to optimize heat exchange
- Hydrophobic treatment improves adiabatic yield and reduces water consumption
- Flow tightness
- Low pressure drop
- Low installation costs
- Easy care and minimal maintenance
- Effective action against noise

Manufacturing

Cross-flow heat exchanger in treated Aluminium. Mechanical assembly of the Plates with Gasket.
Fin spacing from 2.5 to 15 mm.
Size from 200*200 to 2400*2400
Max flow per unit 100 000 m3/h

Options

We offer customized designs of our heat exchangers for data centers.
We can supply:
- Reinforced frame
- Special frame for duct mounting
- Silicone-free Gasket
- By-pass with or without regsiter
- Reinforced sealing ( up to 0.04% at 400 Pa)

Ambiences and applications

Our heat exchangers for data centers are suitable for all types of installations and equipment, whatever the environment.

Materials

Treated aluminium Plates aluminium frame, galvanized steel ...

Standards and certifications

EUROVENT certification, TÛV ...

Focus on data center heat exchanger industries and applications

Domains

AHU Manufacturers

An essential component of AHU (Air Handling Unit) systems designed by AHU manufacturers to heat, cool and filter the air which is then distributed in buildings to ensure optimum thermal comfort and healthy indoor air quality.

AHU Maintenance

Air Handling Unit (AHU) maintenance involves inspecting and cleaning the AHU coil to ensure optimum energy efficiency and healthy indoor air quality.

Configure your Plates heat exchanger
for data centers

To obtain a detailed quotation, a telephone appointment with one of our sales representatives will be scheduled. Please note that this configurator is a tool managed by an algorithm and does not serve as a personalized technical study. For further information, please contact us via the online form.

What are you looking for?