Custom-made, adaptable & versatile – Our air-to-air heat recovery units
Adiabatic air-to-air plate heat recovery units for data centers
Our adiabatic heat recovery units for data centers
TRIANON EXCHANGER offers crossflow air-to-air plate heat recovery units in aluminum for adiabatic applications in data centers. The plates of our heat recovery units feature a hydrophobic treatment to optimize energy efficiency in your data centers. We also provide the option to customize units based on your specific application. Options include enhanced sealing, silicone-free gaskets, and special frames. Highly efficient, our adiabatic heat recovery units for data centers achieve efficiencies of 70% to 90%. They are manufactured with durable materials, CE-compliant, and performance-certified. Depending on your needs, the fins can be spaced from 2.5 mm to 15 mm. Units are also available in a wide range of sizes, from 200×200 mm to 2400×2400 mm.
Adiabatic air-to-air plate heat recovery units for data centers
Technical specifications
Design
Adiabatic air-to-air plate heat recovery units for data centers are designed to significantly improve the energy efficiency of data centers.
They offer several advantages, including:
• High-efficiency counterflow heat exchanger with efficiency above 70%, up to 90%
• Airflow tightness
• Low pressure drop
• Differential pressure up to 4500 Pa
• Low installation cost
• Easy care and minimal maintenance
- Effective action against noise
Materials
Constructed with durable materials:
• Treated aluminum plates
• Aluminum or galvanized steel frame …
Manufacturing
This air-to-air plate heat recovery unit is designed with:
• Crossflow heat exchanger in treated aluminum
• Mechanical plate assembly with sealing gasket
• Fin spacing from 2.5 to 15 mm
• Dimensions from 200×200 to 2400×2400 mm
• Maximum airflow per unit: 100,000 m³/h
Options
Optional custom adiabatic air-to-air plate heat recovery units for data centers can be provided with:
• Enhanced sealing (up to 0.04% at 400 Pa)
• Bypass with or without dampers
• Special frame for duct installation
• Reinforced frames
• Silicone-free gaskets
Standards and certification
TÜV certified … CE standards