FAQ – Heat exchangers
How can you prevent a heat exchanger from becoming clogged?
Heat exchanger fouling: causes, risks and solutions
Fouling of a heat exchanger is one of the main causes of performance loss in an industrial plant. It reduces the efficiency of heat transfer, increases pressure drops and can lead to excessive energy consumption, more frequent maintenance or a production shutdown.
In industrial applications, fouling affects heat exchangers, finned coils, heat recovery units and equipment used with air, water, steam, flue gases or process fluids. The extent of fouling depends on the fluids used, operating conditions, temperature, flow velocity, the environment and the design of the equipment.
At Trianon Échangeur, each project is assessed in light of the actual constraints of the installation in order to propose a heat exchanger that is suited to the process, the environment and the energy efficiency targets.
What is fouling in a heat exchanger?
Fouling in a heat exchanger refers to the gradual build-up of deposits on the heat transfer surfaces. These deposits create a barrier between the fluids and the walls of the exchanger, thereby limiting heat transfer. A fouled heat exchanger is therefore forced to operate under less favourable conditions. Thermal output decreases, pressure drops increase, and the system may consume more energy to achieve the same result. In some cases, fouling can also accelerate corrosion, make cleaning more difficult or reduce the equipment’s service life.
What are the implications for industrial performance?
A fouled heat exchanger gradually loses efficiency. Heat is transferred less effectively between the fluids, which can lead to a drop in temperature on the air or fluid side, insufficient thermal output or a decline in process performance. Fouling can also increase pressure drops. Fans, pumps or associated equipment must then work harder to maintain the desired flow rate. This can lead to increased energy consumption and greater strain on the system.
The main consequences are:
- decrease in thermal efficiency
- increase in pressure drops
- excessive energy consumption
- more frequent maintenance
- risk of accelerated corrosion
- loss of cooling or heating capacity
- production stoppage in the event of severe blockage
- early replacement of the heat exchanger
What are the main types of fouling?
Fouling can take various forms depending on the fluids and the operating environment.
- Particulate fouling
It is caused by the build-up of dust, fibres, particles or solid deposits. It is common in industrial ventilation systems, air handling units, processes involving contaminated air, or dusty environments.
In a finned heat exchanger, particulate build-up can gradually obstruct the airflow and significantly reduce thermal performance.
- Corrosion-induced fouling
Corrosion can lead to the formation of deposits, oxides or surface damage. It occurs in particular when materials are unsuitable for the environment, humidity, chemical agents or the nature of the fluids.
In this case, the choice of materials and surface treatments becomes crucial.
- Biological fouling
It may occur in certain systems that use water or fluids conducive to biological growth. It can cause deposits to form, restrict the flow of fluid and impair the heat exchanger’s performance.
- Chemical fouling
Certain fluids can cause reactions or deposits on heat exchange surfaces.
This phenomenon depends on the fluid’s composition, temperature, operating time, and flow conditions.
How can you minimize fouling in a heat exchanger?
Fouling control begins as early as the design phase. A heat exchanger must be selected and sized based on the fluids, temperatures, flow rates, cleaning requirements, and installation environment.
There are several ways to reduce the risk of clogging.
- Adapting heat exchanger technology
The choice of technology depends on the type of fluid, the presence of particles, the humidity level, temperatures, and ease of access for maintenance.
A finned coil, an air-to-air heat exchanger, a flue gas heat recovery unit, or a fluid-to-fluid heat exchanger are not subject to the same fouling constraints. The choice must therefore be based on the actual process, and not solely on the required thermal capacity.
- Choosing the Right Fin Pitch
In a finned heat exchanger, the fin pitch plays an important role. A pitch that is too tight can promote the accumulation of dust or deposits in a contaminated environment.
In applications exposed to dust, fibers, or particles, a wider fin spacing can facilitate airflow and make it easier to maintain the equipment.
- Plan for ease of cleaning
A heat exchanger that is difficult to clean becomes clogged more quickly over time. Access to heat exchange surfaces, filters, condensate pans, and retention areas must be taken into account during the design phase.
In some cases, a custom design allows for adjustments to the frame, connections, access hatches, or layout to facilitate maintenance.
- Selecting the Right Materials
The materials must be compatible with fluids, moisture, temperatures and the environment. Stainless steel, copper, aluminium or certain alloys may be considered, depending on the project’s requirements.
In corrosive environments, surface treatment may also be considered to improve the heat exchanger’s resistance.
- Introduce a regular maintenance programme
Even a well-designed heat exchanger must be inspected regularly. The frequency of cleaning depends on the environment, the level of pollution, the nature of the fluids and the rate of operation.
Monitoring temperatures, pressure drops and thermal performance enables any drift caused by fouling to be identified more quickly.
The role of sizing in fouling
Incorrect sizing can lead to fouling in a heat exchanger. An inappropriate flow velocity, an incorrectly calculated heat transfer surface area or an excessively high pressure drop can impair the system’s performance.
The design must take into account:
- air or fluid flow rates
- the inlet and outlet temperatures
- the expected thermal output
- permissible pressure drops
- the nature of fluids
- the expected level of fouling
- cleaning requirements
- the available space
- the necessary materials and treatments
At Trianon Échangeur, the design department analyses these parameters to design a heat exchanger suited to the operating conditions. The aim is to ensure thermal performance whilst taking into account maintenance, durability and integration requirements.
When should a fouled heat exchanger be cleaned or replaced?
Cleaning may be sufficient where the fouling remains accessible and the heat exchanger retains its mechanical integrity. However, replacement may become necessary where the equipment shows a significant loss of performance, advanced corrosion, damaged tubes, severely degraded fins, or where effective cleaning is not possible.
The signs to look out for are:
- drop in outlet temperature
- difficulty in achieving the expected performance
- increase in pressure drops
- increase in energy consumption
- unusual noise or strain on the fans or pumps
- presence of corrosion
- leak in a pipe or manifold
- Recurring blockages despite cleaning
In the event of a replacement, Trianon Échangeur can design a bespoke heat exchanger based on an existing drawing, a model to be replaced, or measurements taken on site.
Trianon Échangeur supports manufacturers, installers, operators and engineering firms in the selection, sizing and replacement of industrial heat exchangers.
Our solutions are tailored to the specific requirements of each application: air, water, steam, flue gases, process fluids, corrosive environments, space constraints, like-for-like replacement or heat recovery.
An analysis of the risk of fouling is one of the factors to be taken into account when designing a high-performance, durable heat exchanger. Depending on your installation, we can advise you on the most suitable technology, a specific fin pitch, a more appropriate material, a surface treatment or a design that facilitates maintenance.
Do you need a heat exchanger suitable for a high-contamination environment?
Have you noticed a drop in performance, recurring blockages or difficulty cleaning your system?
Please contact our design department to discuss your requirements and explore a heat exchange solution tailored to your operational constraints.
A heat exchanger may be fouled if its performance declines, if pressure drops increase, or if the system consumes more energy to achieve the same result. A drop in temperature, insufficient flow rate or the need for increasingly frequent cleaning may also be signs of fouling.
Yes. Fouling can promote corrosion, increase operating stresses and make maintenance more difficult. If deposits are not dealt with, they can reduce the service life of the heat exchanger.
The choice depends on the fluids, temperatures, flow rates, the environment and the nature of the deposits expected. In some cases, it is advisable to opt for a wider fin pitch, specific materials, a surface treatment or a design that facilitates cleaning.
Yes. If the existing heat exchanger is too fouled, corroded or difficult to clean, it can be replaced with an identical unit or adapted to better meet the current requirements of the installation. Trianon Échangeur can work from a drawing, an old heat exchanger or a set of dimensions.
To minimise fouling in a finned heat exchanger, it is necessary to select a suitable fin pitch, maintain effective upstream filtration, ensure access for cleaning, and choose materials that are compatible with the operating environment. The design must also take into account actual operating conditions.