FAQ – Heat exchangers for the pharmaceutical industry

Which heat exchanger should be used in the pharmaceutical industry?

In the pharmaceutical industry, heat exchangers are used not only for air treatment but also for heating, cooling and thermal regulation in manufacturing processes. However, particular care must be taken when selecting them: their thermal performance must be compatible with stringent requirements regarding cleanliness, chemical resistance, leak-tightness and the management of contamination risks.

A heat exchanger used in a purified water circuit is not subject to the same stresses as an air/steam coil installed in an air-handling unit or a heat exchanger exposed to corrosive chemical solutions. The level of requirement depends, in particular, on the equipment’s function, whether it comes into contact with the product, its environment and the cleaning procedures applied.

The most suitable solutions may include stainless steel heat exchangers, steam coils, shell-and-tube heat exchangers, engineering-grade plastic heat exchangers or double-walled equipment. For air treatment, certain membrane-based heat recovery technologies may also be considered, provided they are compatible with the site’s requirements.

Trianon Échangeur offers a range of technologies designed to meet these requirements, with an approach based on actual operating conditions and the project specifications.

What are the specific constraints associated with heat exchangers in the pharmaceutical industry?

In a pharmaceutical environment, thermal design is only one part of the assessment. A piece of equipment may meet the required power output whilst having characteristics that are unsuitable for its intended use: retention areas that are difficult to clean, materials that are sensitive to chemicals, leaks, or the inability to inspect surfaces in contact with the fluid.

The first distinction concerns the position of the heat exchanger within the system.

A heat exchanger fitted to a closed technical loop can be isolated from the pharmaceutical product. Conversely, a heat exchanger used with purified water, water for injections or a fluid directly involved in the process requires greater attention to surface cleanliness, leak-tightness and the risk of contamination.

In air-handling systems, priorities include temperature stability, pressure drops, the cleanliness of components, condensate drainage and integration into the air distribution networks.

These differences explain why there is no single universal heat exchanger for the pharmaceutical industry.

What standards and regulations govern pharmaceutical thermal equipment?

The pharmaceutical sector is subject to a strict regulatory framework. The requirements applicable to a heat exchanger depend on its function, its location, its level of criticality and the specifications set by the pharmaceutical manufacturer.

Good Manufacturing Practice (GMP): cleanliness, design and risk management

In Europe, Good Manufacturing Practices, also known as GMP (Good Manufacturing Practices), are set out in the EudraLex Volume 4 guide.

Several sections are particularly relevant to thermal equipment:

  • Chapter 3, Premises and equipment: design suited to the intended use, ease of cleaning, maintenance and prevention of contamination risks.
  • Chapter 5, Production: Prevention of contamination and cross-contamination in manufacturing processes.
  • Appendix 1, Manufacture of sterile medicinal products: specific requirements for the control of microbial, particulate and endotoxin or pyrogen contamination.
  • Appendix 15, Qualification and validation: principles for demonstrating that facilities, equipment and processes meet the defined requirements.

Annex 1 relates specifically to sterile manufacturing processes. It therefore does not automatically apply to all heat exchangers used in a pharmaceutical plant.

In practice, GMPs involve assessing the cleanability of equipment, the compatibility of materials, the risk of leaks, inspection procedures and the documentation required for its qualification within the facility.

ISO 14644 standard: cleanliness control in cleanrooms

For facilities containing cleanrooms or controlled-atmosphere areas, the ISO 14644 series is an important standard.

The ISO 14644-1 standard defines the classification of air cleanliness based on the concentration of airborne particles. The ISO 14644-2 standard relates to the monitoring of particle cleanliness performance in cleanrooms.

The ISO 14644-14:2026 standard, for its part, describes a method for assessing the suitability of equipment for use in a cleanroom in terms of airborne particles.

These specifications relate, in particular, to the conditions for integrating equipment into a controlled environment. In addition to these, there are requirements relating to sanitary design, cleanability and thermal performance.

Pressure Equipment Directive (PED)

Heat exchangers operating under pressure conditions covered by the regulations must also comply with the relevant requirements of European Directive 2014/68/EU, known as the DESP.

This Directive applies, subject to its exclusions, to pressure equipment with a maximum allowable pressure exceeding 0.5 bar.

In the case of a vapour heat exchanger or a pressurised fluid-to-fluid heat exchanger, particular consideration must be given to the operating conditions, the nature of the fluid, the volumes involved and the regulatory category.

Other technical or health-related standards, such as ASME BPE or certain 3-A requirements, may apply where they are specified for the product, market or application.

Regulatory compliance must be assessed for each piece of equipment and its intended use. It cannot be deduced solely from the choice of a material or a technology.

What standard of manufacturing cleanliness is required in the pharmaceutical industry?

The cleanliness of a heat exchanger is not limited to its external appearance. Depending on its intended use, the equipment may be subject to specific requirements regarding the quality of welds, surface finish, the absence of manufacturing residues, cleaning prior to delivery, or the protection of circuits against the ingress of particles. Ensuring a tight seal between the two fluids in the heat exchanger is often essential to prevent the risk of contamination.

Manufacturing processes may, in particular, leave traces of machining oils, greases, metal particles, dust or residues resulting from mechanical operations. Where the specifications require it, specific operations and checks must be carried out:

  • cleaning and degreasing of components
  • inspection of welds and surface condition
  • checking that there are no visible foreign objects
  • leak test carried out in accordance with a suitable procedure
  • protection of connections and openings after cleaning
  • packaging designed to minimise the risk of recontamination during transport
  • provision of the requested documents and certificates.

In the case of sanitary circuits, the geometry must also minimise areas where water can accumulate and allow for effective drainage and cleaning. Surface roughness may be one of the specified characteristics.

A distinction must be made between manufacturing cleanliness, cleanability and sterility. A heat exchanger that has been carefully cleaned and conditioned is not automatically sterile. Any requirements for microbiological decontamination, sterilisation or validation must be explicitly defined and verified.

How can heat exchangers be protected from corrosive chemicals?

Les échangeurs thermiques utilisés dans les industries pharmaceutique, biopharmaceutique et chimique peuvent être confrontés à des substances agressives pour les matériaux.

Depending on the application, this exposure may arise from process fluids, clean-in-place (CIP) solutions, disinfectants or even the surrounding atmosphere.

Acids, alkaline solutions, chlorinated compounds, oxidising agents and certain solvents can cause different types of corrosion.

316L stainless steel is commonly used in sanitary equipment, particularly due to its resistance to a wide range of environments and its suitability for various surface finishes. However, it is not universally resistant to all chemicals.

For example, certain conditions of exposure to chlorides can promote localised corrosion. High temperatures, chemical concentrations and contact times can also alter the behaviour of the material.

The choice must therefore be based on the exact composition of the fluids, their concentration, the temperature, the cleaning conditions and the risk of long-term corrosion.

Where stainless steel is not the most suitable solution, the use of anti-corrosion treatments or chemically compatible engineering plastics may offer a viable alternative.

What solutions does Trianon Échangeur offer for the pharmaceutical industry?

Trianon Échangeur offers several ranges of solutions, from stainless steel coils for air handling to sanitary heat exchangers with enhanced separation, as well as plastic heat exchangers for chemically aggressive fluids.

Air/steam coil and stainless steel heat exchanger

Stainless steel fin-and-tube heat exchangers can be used to heat process air or treated air in a pharmaceutical plant.

An air/steam heat exchanger transfers energy from the steam to the air stream, without any direct contact between the two fluids under normal operating conditions.

In accordance with the specifications, the design may incorporate 304 or 316L stainless steel tubes, fins and frames suited to the environment, as well as specific sealing requirements for the frame.

Steam management also requires consideration to be given to condensate drainage, variations in thermal load, thermal expansion stresses and the risk of water hammer.

In air handling systems, pressure drops must remain compatible with the fans and the operating conditions of the network. These coils can be used, for example, for process air heating, for installation in air handling units, or to replace existing equipment where the dimensions and connections must be retained.

Custom steam batteries

Sanitary tubular heat exchanger in a calender

For applications requiring enhanced contamination control, the range offers a specific technical solution. These are 316L stainless steel sanitary shell-and-tube heat exchangers, designed specifically for applications involving high-purity fluids, such as purified water (PW) or water for injection (WFI).

Their design has several particularly interesting features:

  • Double tubular plate: this reinforces the separation between the clean fluid and the working fluid, whilst enabling the detection of any leaks in the intermediate space.
  • Polished internal surfaces: surfaces in contact with the clean medium may have a surface roughness of Ra ≤ 0.5 µm, in accordance with the range’s specifications.
  • Drainability: the geometry and connections are designed to allow drainage by gravity in the intended configuration.
  • 316L stainless steel construction: designed for sanitary applications compatible with this material.
  • Raccordements sanitaires : possibilité de connexions de type Tri-Clamp selon la configuration.

These features address specific challenges: minimising retention areas, facilitating cleaning and reducing the consequences of a leak. In particular, the heat exchanger can be designed for purified water circuits, the production or distribution of water for injectable preparations, and installations requiring enhanced separation between the product and the heat source.

Sanitary tubular heat exchanger in a calender

Spiral tube heat exchanger

Spiral-wound stainless steel tube heat exchangers offer another solution for certain heating and cooling requirements. Their design is based on a bundle of tubes arranged in a spiral within a heat exchanger shell. This configuration provides a large heat transfer surface area within a relatively compact footprint and can promote fluid turbulence depending on the flow conditions.

  • All-stainless steel grille – 316, 316L, 321
  • High-efficiency helical coaxial tubes for heat exchange
  • Vertical connection to minimise the space taken up by the heat exchanger within the system
  • Withstands high pressures (35 bar) and high temperatures (250°C)

They are often used in steam, hot water or superheated water circuits, and in applications requiring a suitable mechanical design. However, a distinction must be made between an industrial spiral-tube heat exchanger and a sanitary heat exchanger specifically designed for a critical pharmaceutical fluid. The required standards for cleanliness, drainability and leak-tightness are not necessarily the same.

Custom spiral tube heat exchangers

Plastic heat exchanger

In certain applications, chemical resistance is a priority. Conventional metal heat exchangers may therefore reach their limits when exposed to acids, alkaline solutions or other aggressive fluids. Plastic heat exchangers offer a viable solution for heating or cooling processes involving chemically demanding substances.

Depending on the technology and application, a number of materials may be considered:

  • Polypropylene (PP): suitable for a wide range of compatible chemical applications.
  • Polyethylene (PE, PE-RT): used in certain applications requiring suitable chemical resistance and thermal stability.
  • PVDF: suitable for use in various aggressive chemical environments, subject to compatibility with the substance and temperature.
  • PFA: suitable for certain applications requiring high levels of chemical resistance and purity.

These heat exchangers may be particularly suitable for use in process baths, corrosive liquid circuits or applications where contact with certain metals must be avoided. However, the choice should not be based solely on the description ‘corrosion-resistant plastic’. Each polymer has its own limitations in terms of chemical compatibility, temperature and pressure.

Double-walled or double-plate heat exchanger

An internal leak can have serious consequences if a process fluid enters a circuit containing a product or a high-purity fluid.

To minimise this risk, double-walled or double-plate heat exchangers may be considered.

The principle involves introducing an additional barrier between the two circuits. Depending on the design, a leak in the first wall can be channelled outwards or towards a detection zone, rather than leading directly to the fluids mixing.

A distinction must be made between two families.

Échangeurs à plaques et joints à double parois

Certain configurations of plate heat exchangers with removable gaskets allow for a double separation between the fluids. These may be appropriate where access to the plates, maintenance and leak detection form part of the specifications.

Brazed, double-walled plate heat exchangers

The technology is based on double-walled brazed plates, with a mechanism designed to make any external leak detectable under the conditions specified in the design. It may be of interest for compact applications requiring enhanced circuit isolation.

In both cases, double separation is a risk-reduction measure. The choice must take into account the pressure differential, the method of leak detection, material compatibility, maintenance and the criticality of the fluid.

Counter-current membrane heat exchanger

Air handling also accounts for a significant proportion of energy consumption in certain pharmaceutical buildings and facilities.

Where site conditions permit, an air-to-air membrane heat exchanger can transfer sensible heat as well as some of the moisture between two air streams.

The membrane heat recovery units we offer use a polymer membrane designed to enable heat and moisture exchange without the air streams mixing directly.

This technology may be of interest for controlling humidity levels and reducing the need for heating, cooling or humidification, whilst eliminating the risk of contamination.

In a pharmaceutical environment, however, its integration requires a specific assessment: the nature of the extracted air, chemical or microbiological risks, airtightness, membrane integrity, pressure differentials and cross-contamination requirements.

The expected level of separation must be demonstrated by the performance and testing applicable to the equipment. Moisture recovery must not automatically be equated with the absolute absence of contaminant transfer.

Heat recovery units with moisture transfer Plates

A practical application: two 316L stainless steel air/steam heat exchangers for sensitive environments

The replacement of existing heat exchangers is a good illustration of the complexity of certain projects in industries with stringent cleanliness requirements.

Trianon Échangeur has, in particular, manufactured two air/steam heat exchanger banks for an application intended for the biopharmaceutical, cosmetics and baby food sectors.

The project had a number of specific requirements:

  • seamless, drawn 316L stainless steel tubes
  • watertight housing on the process air circuit
  • reproduction of the existing configuration
  • taking integration constraints into account
  • thorough cleaning at the end of the manufacturing process.

These technical choices addressed concerns that went beyond mere thermal design: material quality, leak-tightness, cleanliness on delivery and ensuring compatibility with the existing process. This project demonstrates the importance of defining requirements precisely right from the design stage. A standard heat exchanger does not necessarily meet the manufacturing and cleanliness requirements expected in this type of environment.

How do you choose the right solution for a pharmaceutical process?

The solution depends first and foremost on what the heat exchanger is required to do and on the nature of the fluids involved.

  • To heat process air using a steam network, a stainless-steel air/steam heat exchanger may be appropriate.
  • For a purified water circuit or a high-purity fluid requiring a specific sanitary design, a P-Line heat exchanger may be considered.
  • Where resistance to aggressive chemicals is a key consideration, CALORPLAST plastic heat exchangers offer a viable alternative to metal designs.
  • If the separation of fluids is particularly critical, double-walled or double-plate technology can help to minimise the consequences of a leak.
  • In compatible air-handling systems, a membrane heat exchanger may be considered to recover some of the energy and humidity.

Before selecting a solution, it is essential to check the thermal and hydraulic data, the composition of the fluids, the cleaning conditions, the installation environment and the site’s documentation and regulatory requirements.

Trianon Heat Exchanger: solutions tailored to the requirements of the pharmaceutical sector

The role of the design office is to translate process requirements into specific technical choices: heat exchange technology, materials, sealing, geometry, connections, pressure drops and maintenance requirements.

Whether for a new installation or a replacement, Trianon Échangeur analyses the operating parameters and integration requirements in order to guide the project towards the most suitable solution.

The study may be based on specifications, drawings, operational data, photographs or a dimensional survey of the existing equipment.

Are you looking for a heat exchanger suitable for a pharmaceutical process, a corrosive fluid circuit or a system requiring specific manufacturing cleanliness standards?

Transmettez les conditions de fonctionnement et les exigences de votre installation afin d’étudier la solution thermique la plus appropriée.

Contents

316L stainless steel is frequently used in sanitary applications due to its properties and its ability to be finished to suitable surface conditions. However, it is not suitable for all chemical environments. For certain particularly corrosive fluids, engineering plastics such as PVDF, PP or PFA may be considered, subject to verification of their compatibility.

The equipment must comply with the requirements applicable to its use and with the site’s quality system. GMPs provide guidance, in particular, on the design and use of equipment, its cleaning, maintenance and the control of contamination. The specific requirements depend on the role of the heat exchanger and the criticality of the process.

A double-walled heat exchanger enhances the separation between two fluids. Depending on its design, a leak in one wall can be detected before the circuits become mixed. This solution is particularly useful where there is a significant risk of a clean fluid becoming contaminated by a thermal utility.

A stainless steel fin-and-tube heat exchanger is primarily designed for heat transfer between air and a fluid, particularly for heating process air. A P-Line heat exchanger is a sanitary tube-and-shell heat exchanger designed for specific applications involving high-purity fluids. It features, in particular, a double tube sheet and polished internal surfaces.

Yes, provided the plastic material is compatible with the product and the operating conditions. CALORPLAST heat exchangers can be manufactured from PP, PE, PVDF or other engineering polymers, depending on the product range. The selection must take into account the chemical concentration, temperature, pressure and duration of exposure.

Cleanliness is based on manufacturing and control requirements set out in the specifications: surface quality, cleaning, degreasing, inspection, protection of openings and appropriate packaging. Where microbiological or sterility requirements apply, additional procedures and validations are necessary.

What are you looking for?