Our projects
Finned tubular heat exchangers
Identical replacement of a 7.5 m long and 2.5 m high finned tubular heat exchanger, specially designed for a steel mill and rolling mill.
Mission
Trianon Échangeur faced several challenges: an identical replacement of a 7.5 m long and 2.5 m high finned tubular heat exchanger, specially designed for a steel mill and rolling mill. This complex project required meticulous dimensional surveying and flat lifting in preparation for delicate crane handling.
The challenges?
◾ Replacement with strictly identical dimensions despite its large size.
◾ Flat lifting for rooftop installation (2403 kg)
◾ Ensure exchanger performance by changing the fabrication technology from a water box to a header collector.
Our answer
◾ Length: 7.5 m | height: 2.5 m
◾ Reinforced copper tubes: 1.0 mm thickness
◾ Aluminum fins: 0.40 mm thickness
◾ Stainless steel frame: 4.0 mm thickness
◾ IPN beams & lifting plates: 10 mm thickness
◾ Cover boxes for collector protection
◾ 6” stainless steel flanges for unbeatable reliability