Identical replacement of a 7.5 m long and 2.5 m high finned tubular heat exchanger, specially designed for a steel mill and rolling mill.

Mission

Trianon Échangeur faced several challenges: an identical replacement of a 7.5 m long and 2.5 m high finned tubular heat exchanger, specially designed for a steel mill and rolling mill. This complex project required meticulous dimensional surveying and flat lifting in preparation for delicate crane handling.

The challenges?

◾ Replacement with strictly identical dimensions despite its large size.

◾ Flat lifting for rooftop installation (2403 kg)

◾ Ensure exchanger performance by changing the fabrication technology from a water box to a header collector.

Our answer

◾ Length: 7.5 m | height: 2.5 m

◾ Reinforced copper tubes: 1.0 mm thickness

◾ Aluminum fins: 0.40 mm thickness

◾ Stainless steel frame: 4.0 mm thickness

◾ IPN beams & lifting plates: 10 mm thickness

◾ Cover boxes for collector protection

◾ 6” stainless steel flanges for unbeatable reliability

Thanks to this specific design, our solution guarantees durability and optimal integration, while facilitating lifting operations. Once again, Trianon Échangeur demonstrates its expertise in delivering complex technical projects in support of industrial performance.