FAQ – Heat exchangers

Can a heat exchanger be replaced with an identical one?

Can a heat exchanger be replaced with an identical one?

Yes, a heat exchanger can be replaced with an identical unit provided that its dimensions, connections, thermal performance and installation requirements are correctly recorded.

This solution is particularly suitable when an existing heat exchanger has a leak, a broken tube, advanced corrosion, a loss of performance, or when it becomes difficult to maintain. Replacing it with an identical unit allows the available space, mounting points, connections and integration into the existing system to be retained.

Trianon Échangeur supports manufacturers, installers, operators and engineering firms in the replacement of bespoke heat exchangers, based on a drawing, an existing model or measurements taken on site.

When should a heat exchanger be replaced?

A heat exchanger may need to be replaced when its condition no longer allows it to deliver the expected performance or when it is no longer viable to repair it.

The most common cases are:

  • leak in a pipe, manifold or connection
  • severe corrosion
  • heavily damaged fins
  • build-up that cannot be cleaned properly
  • heat loss
  • excessively high pressure drops
  • mechanical failure
  • obsolescence of the existing model
  • lack of standard spare parts
  • changes to operating conditions

In many cases, replacing the component with an identical one is the simplest solution to minimise changes to the installation.

It avoids the need to replace all the pipework, supports, frame or integration into an air handling unit, duct, industrial process or existing equipment.

What is a like-for-like replacement?

An identical replacement involves manufacturing a new heat exchanger that matches the key specifications of the existing unit.

The aim is to preserve:

  • overall dimensions
  • the available space
  • the connections
  • the centre-to-centre distances
  • the direction of flow of fluids
  • the position of the manifolds
  • the setting
  • the fixings
  • the required thermal performance
  • installation and maintenance requirements

This type of replacement is common for finned heat exchangers, hot-side heat exchangers, cold-side heat exchangers, steam heat exchangers, air/water, air/steam and air/flue gas heat exchangers, or heat recovery units fitted to existing equipment.

Replacing a unit with an identical one does not necessarily mean replicating every detail of the old heat exchanger exactly. It can also provide an opportunity to improve certain aspects: materials, frame thickness, surface treatment, ease of cleaning, corrosion resistance or adaptation to actual operating conditions.

What information is needed to replace a heat exchanger?

To replace a heat exchanger with an identical model, it is necessary to gather as much information as possible about the existing equipment and how it operates.

Useful data includes, in particular:

  • overall dimensions
  • frame dimensions
  • number of rows
  • blade fins
  • type of tubes and fins
  • position of the manifolds
  • diameter and type of connection
  • centre-to-centre distances between fittings
  • direction of fluid flow
  • air or fluid flow rate
  • inlet and outlet temperatures
  • operating pressure
  • fluid used
  • expected thermal output
  • installation environment
  • access and installation constraints

Photographs of the existing interchange, its junctions and the surrounding area are also very useful for analysing the project.

Where equipment is difficult to access, taking precise measurements helps to ensure the manufacturing process runs smoothly and minimises the risk of errors during assembly.

Is it possible to replace a heat exchanger without the original drawings?

Yes, it is possible to replace a heat exchanger without the original drawings. In such cases, the design office can work from the old heat exchanger, a set of measurements, photographs, installation drawings or technical information available on site.

This situation is common in older installations, existing air-handling units or equipment where the original manufacturer is no longer known.

Taking measurements therefore becomes a crucial step. It provides the dimensions required to design the new heat exchanger: overall dimensions, connections, centre-to-centre distances, frame, manifolds, flow direction and installation constraints.

If the survey is complex, Trianon Échangeur can look into the possibility of providing specialist support to ensure that measurements are taken accurately and that the technical specifications for the replacement are defined correctly.

Replacement with an identical model or technical adaptation?

Replacing components with identical ones is often the preferred option to simplify installation. However, it may be appropriate to adapt certain components where operating conditions have changed.

For example, a heat exchanger can be replaced with:

  • a material better suited to a corrosive environment
  • an anti-corrosion surface treatment
  • a different fin pitch to minimise fouling
  • a strengthened framework
  • suitable connections
  • a design that makes cleaning easier
  • thermal performance recalculated to meet current requirements

This approach makes it possible to retain the mechanical integration of the existing heat exchanger whilst improving its durability, maintainability or energy efficiency.

The role of the design office is therefore to assess whether a strict replica is the best solution, or whether a technical adaptation could bring real benefits to the installation.

Trianon Échangeur designs bespoke heat exchangers to replace existing equipment in a variety of industrial settings.

The analysis can be carried out using a plan, an existing model, a set of dimensions or technical specifications. The design office takes into account constraints relating to performance, space requirements, connections, materials, pressure, temperature and the environment.

This approach enables us to offer a solution tailored to existing installations, whether the requirement is for a finned coil, a CTA coil, an air-to-water, air-to-steam or air-to-flue gas heat exchanger, or a heat recovery unit.

Do you need to replace an existing heat exchanger? Do you need to replace a heat exchanger that is broken, corroded, fouled or obsolete?

Please send us your plans, photographs, dimensions or technical details. Our teams will analyse your requirements to design a bespoke heat exchanger, tailored to your installation and your operational constraints.

What are you looking for?